WHAT IT DOES
Every ticket reproduces when an auditor recalculates it
Measurement is where the accounting numbers start. A liquid ticket takes the opening and closing meter readings, corrects the indicated volume for temperature, pressure and meter performance, and takes out sediment and water to give net standard volume. Converge HCA records each step to the decimals the standard sets and rounds it once, so the ticket gives the same answer every time it is recalculated.
Meter proving produces the meter factor the tickets use. Converge HCA calculates it by the average-data or the average-meter-factor method, checks repeatability and keeps each meter’s factor history. A factor outside its limits is refused, and a change of more than 0.0025 between provings takes the meter out of service, applies the average back to the last good proving and re-runs the affected tickets as adjustments.
Gas volumes are corrected to base conditions with compressibility from AGA-8 DETAIL or GERG-2008, and the gas analysis gives heating value, relative density and Wobbe index at the reference conditions your contract names. Volume and heating value are never combined across different bases.